Search results for " watch glass"
showing 7 items of 7 documents
Watch glasses exposed to 6 MV photons and 10 MeV electrons analysed by means of ESR technique
2011
ESR study of proton irradiation response of watch glasses.
2009
Preliminary application of thermoluminescence and single aliquot regeneration method for dose reconstruction in soda lime glass
2013
The research described in this paper shows that the use of the single aliquot regeneration (SAR) method for thermoluminescence (TL) measurements applied to soda lime glasses allows to carry out a retrospective dose evaluation. We have followed a fast and efficient sample preparation procedure which permits measurements without powdering and sieving processes. We have analyzed the TL signal of commercial soda lime watch glass irradiated with 6 Mega Volts (MV) LINAC photons, 10 MeV LINAC electrons and 62 MeV protons. After the initial exposure and following TL reading, the samples are successively irradiated with increasing doses of photons. Therefore, for each sample its calibration curve is…
ESR response of watch glasses to neutron irradiation
2012
Abstract In this paper we report the results of the electron spin resonance (ESR) study of the radiation-induced signal of watch glasses exposed to neutrons. This work extends the series of analyses of the response of watch glasses to various radiation beams which our research group is carrying out for possible applications in retrospective dosimetry. We have considered fluences up to about 3 × 1011 cm−2. We evaluated the signal fading and we found that in the first hours after exposure the signal rapidly decreases. After about 1000 h, it decreases much more slowly. The signal was reduced by about 25% in about 5 months. The radiation induced signal is found to be linearly dependent on neutr…
Watch glasses exposed to 6 MV photons and 10 MeV electrons analysed by means of ESR technique: A preliminary study
2011
Abstract In this work we report a case study of the ESR response of watch glasses exposed to 6 MV photons and to 10 MeV electrons. The choice of watch glasses is justified by the fact that watch glasses are very close to the exposed individual. For both types of radiation beams, the absorbed doses belong to the range between 1 and 20 Gy. The samples have been irradiated in water-equivalent plastic phantom with a linear accelerator used for radiotherapy. After exposure watch glass samples have been cut in small strip-shaped pieces with suitable size to be put into the quartz tube for ESR measurements. The signal induced by radiation (RIS) lies in the g ∼ 2 region and must be discriminated fr…
TL dose reconstruction in watch glasses exposed to photon, electron and proton beams
2010
Thermoluminescence response of sodalime glass irradiated with photon and electron beams in the 1-20 Gy range
2011
Abstract The thermoluminescence response of a watch commercial glass was studied after irradiation with photons and electrons, in the range 1–20 Gy, of interest in accidental dosimetry; a linear response was obtained with both beams. This result, together with the satisfactory time stability of the thermoluminescence signal, indicates this glass as a potential material for retrospective dosimetry applications.